Scanning system | |
| Drum |
Point sampling with Photomultiplier tube |
| Image recorder |
Parallel recording image point in a 3 x RGB Photomultiplier |
| Aperture |
Fully automatic aperture setting |
| Signal resolution |
special HW for the calculation of the adjustable scale in the scanner |
| Image Processing Hardware |
|
| Autoscaling |
special HW for the calculation of the adjustable scale in the scanner |
| Autosharpening |
special HW for optimal and fast USM calculations in the scanner |
| Scanning resolution |
|
| Color / halftone / line |
max. 4330 L / cm (11,000 dpi) |
| Scale |
|
| Color / halftone / line |
20 - 3000 % |
| Scale calculation |
Steplessly with Autoscaling hardware in 0.1% increments |
| Differentiable density range |
3.9D measured on the output of a film with a grey wedge |
| Resolvable density |
4.2D measured on the output of a film with a grey wedge |
| Template types |
supervision and inspection, color and black and white, halftone and line template, positive and negative |
| Template Thickness |
max. 2 mm |
| Drum speed |
max. 1800 U/min |
| Interfaces |
SCSI-2 for workstation connection |
| Voltage |
85 - 240 VAC, 47 - 63 Hz |
| Power consumption |
ca. 500 W |
| Ambient |
18 - 28 °C, 30 - 80 % relative humidity |
| Dimensions (WxHxD) |
ca. 620 x 1507 x 660 mm, height of 2160 mm for cylinder change |
| Weight |
approx 250 kg |
| Approvals |
GS, UL, cUL, GOST/CE, FCC, ACN, CNS |